200F
30
67.5
SCSCA1B200ZB00MV00
600F
50
75
SCSCA1B600ZD00MV_ _
1200F
50
101
SCSCA1C120ZC00MV_ _
2700F
75
105
SCSCA1C270ZE00MV00
5000F
100
105
SCSCA1C500ZG00MV00
6500F
100
130
SCSCA1C650ZH00MV00
The extension of the SuperCap C range offer the possibility of achieving nearly every
capacitance or voltage value by cascading of the cells. The cost-effective manufacturing
of the components in cylindrical cases enables convenient substitution of other brands.
Technical Data
Capacitance:
CN
110 F
200 F
600 F
1200 F
2700 F
5000 F
6500 F
Capacitance
tolerance:
-
±20%
±20%
±20%
Rated
voltage:
UR
2.5V
2.5V
2.5V
Rated current:
IC
30A
45A
400A
650A
900A
1000A
1000A
Pulse current:
IP
up to 220A
up to 400A
up to 1400A
up to 2400A
up to 4000A
up to 5000A
up to 5000A
Internal
resistance:
RDC
9m
6m
1.2m
0.5m
0.3m
0.2m
0.18m
Max. stored energy: ±20%
Emax.
344J
625J
1875J
3750J
7.5kJ
15kJ
18kJ
Operating
temperature:
Top
-30°C ... +65°C
-30°C ... +65°C
-30°C ... +65°C
Storage temperature:
Tst
-40°C ... +70°C
-40°C ... +70°C
-40°C ... +70°C
Weight:
m
40g
65g
170g
235g
620g
1000g
1250g
Volume:
V
0.034l
0.056l
0.13l
0.18l
0.46l
0.83l
1.0l
Additional Data
Case:
-
Al99.5
Al99.5
Al99.5
Terminations:
-
Solder pin/4 lug terminals
Weld terminations Ø28
Weld terminations Ø60
.
Comparative Data
Lifetime:
in hours 1):
h
90000
90000
90000
in cycles 2) :
Cycles
500000
500000
500000
Energy
density:
gravimetric:
Ed
2.4Wh/kg
2.7Wh/kg
3Wh/kg
4.6Wh/kg
3.6Wh/kg
4.2Wh/kg
4.3Wh/kg
volumetric:
Ev
2.8Wh/l
3.1Wh/l
3.7Wh/l
9.5Wh/l
4.8Wh/l
5Wh/l
5.2Wh/l
1) Requirements:
lC/CNl < 30%, ESR < 2 times specified limit, Ipeak< 2 times of initial value.
1) Test conditions:
lC/CNl < 30%, ESR < 2 times specified limit, Ipeak< 2 times of initial value
(cycles: charging to UR, 30sec rest, discharging to UR/2, 30sec rest).
New values
-
Laser welded aluminium plates for series or parallel connection (cascading) of the single cells (optional)
UR
CN
D
L
L1
2.5 V
600 F
1200 F
50
50
67
93
75
101
Part number completion:
Standard:
Aluminium plates:
= 00
= 0L
UR
CN
Dimensions
D
D1
L
L1
2.5 V
110 F
200 F
25
30
25
30
67.5
67.5
5
6
Dims. in mm.
When connected in series cases should be kept
isolated.
Rights reserved to amend design data without